06 / SE Series · Server Emulator

Server Emulator
Load Banks

A data hall full of load, before a single server ships. SE-Series rack-mounted emulators reproduce the exact electrical draw and front-to-back thermal output of live IT racks — letting you commission cooling, airflow and power distribution against a realistic, controllable heat map.

Per Rack
5–60 kW
Form
42U rack
Airflow
Front-to-back
Control
Network / BMS
Ashford server emulator load bank — 42U rack

Overview

Real rack load,
fully programmable.

Cooling and airflow can only be proven against a realistic heat load distributed exactly as servers will sit. The SE-Series places programmable load and matched fans inside standard rack units, so each rack draws its rated kW and exhausts heat front-to-back like the IT it stands in for — validating containment, CRAC/CRAH performance and CFD models before go-live.

Every unit is individually addressable over the network, so an entire hall can be ramped, stepped and patterned from one console to simulate steady-state, peak and fault scenarios — and to map hot spots while there is still time to correct them.

Form Factor
Standard 19" rack, 42U configurations
Per-Rack Load
5–60 kW, fine-step programmable
Airflow
Front-to-back, server-matched fan profiles
Control
Per-unit network addressing, BMS integration
Metering
Per-rack kW and inlet/outlet temperature

Product range

SE Series
ratings.

A representative selection of the standard SE-Series range. Per-rack load, form factor and fan profile are configurable — systems are engineered to the white-space design.

Model Per-Rack Load Voltage Form Factor Airflow Control
SE-55 kW230 V6U moduleFront-to-backNetwork
SE-1010 kW230/400 V12U moduleFront-to-backNetwork
SE-2020 kW230/400 VRack (partial)Front-to-backNetwork/BMS
SE-3030 kW400 V42U rackFront-to-backNetwork/BMS
SE-4545 kW400 V42U rackFront-to-backNetwork/BMS
SE-6060 kW400 V42U rackFront-to-backNetwork/BMS

Representative range — figures configurable to order.

Engineering

Built into every unit.

01

Server-Matched Thermal

Front-to-back airflow that mirrors live IT equipment.

02

Per-Rack Programmability

Set each rack’s kW independently across the hall.

03

Hall-Wide Orchestration

Ramp and pattern every unit from one console.

04

Containment Validation

Prove hot-aisle / cold-aisle and containment performance.

05

CFD Correlation

Verify thermal models against measured reality.

06

Network Addressable

Full data logging and BMS integration per unit.

Applications

Where SE-Series
earns its place.

Wherever cooling and airflow must be proven against a realistic IT heat load.

White-Space Commissioning Cooling & Airflow Validation Containment Testing CFD Correlation Hyperscale Fit-Out Colocation Edge Data Centres Hot-Spot Mapping Capacity Planning Re-Commissioning

Specify your
SE-Series system.

Send us your rack layout and per-rack load targets and our engineers will configure the emulator system and quote it, typically within one working day.